Archives of Acoustics,
1, 4, pp. 299-308, 1976
Analysis of the initial fraction of bekesy recordings in the thre- shold audiometry*
Statistical analysis of initial transients in the threshold Bekesy tracings, observed mostly at higher rates of the signal level control (i.e. 10 dB /s and 30 dB /s), is given. The transients reach several dB and last about 10 s. Pos¬sible background of psychological nature is discussed.
Full Text:
PDF
Copyright © Polish Academy of Sciences & Institute of Fundamental Technological Research (IPPT PAN).