Archives of Acoustics, 41, 2, pp. 323–330, 2016
10.1515/aoa-2016-0033

Perception of Changes in Spectrum and Envelope of Musical Signals vs Auditory Fatigue

Maurycy KIN
Wrocław University of Science and Technology
Poland

Andrzej Dobrucki
Wrocław University of Science and Technology
Poland

The paper presents results of research on an influence of listening fatigue on the detection of changes in spectrum and envelope of musical samples. The experiment was carried out under conditions which normally exist in a studio or on the stage when sound material is recorded and/or mixed. The equivalent level of presented sound samples is usually 90 dB and this is an average value of sound level existing in control room at various recording activities. Such musical material may be treated as a noise so Temporary Threshold Shift phenomenon may occur after several sessions and this may lead to a listening fatigue effect. Fourteen subjects participated in the first part of the experiment and all of them have the normal hearing thresholds. The stimuli contained the musical material with introduced changes in sound spectrum up to ±6 dB in low (100 Hz), middle (1 kHz) and high frequency (10 kHz) octave bands. In the second part of research five subjects listened to musical samples with introduced envelope changes up to ±6 dB in interval of 1 s. The time of loud music exposure was 60, 90 and 120 minutes and this material was completely different from the tested samples. It turned out that listening to the music with an $L_{eq} = 90$ dB for 1 hour influences the hearing thresholds for middle frequency region (about 1–2 kHz) and this has been reflected in a perception of spectral changes. The perceived peaks/notches of 3 dB have the detection ability at 70% and the changes of low and high ranges of spectrum were perceived at the similar level. After the longer exposure, the thresholds shifted up to 4.5 dB for the all investigated stimuli. It has been also found that hearing fatigue after 1 hour of a listening influences the perception of envelope which gets worse of 2 dB in comparison to the fresh-ear listening. When time of listening to the loud music increases, the changes in envelopes which can be detected rise to the value of 6 dB after 90-minutes exposure and it does not increase with further prolongation of listening time.
Keywords: perception of spectral changes; temporary threshold shift; listening fatigue.
Full Text: PDF
Copyright © Polish Academy of Sciences & Institute of Fundamental Technological Research (IPPT PAN).

References

Chiou-Jong C., Yu-Tung D., Yih-Min S., Yi-Chang L., Yow-Jer J. (2007), Evaluation of auditory fatigue in combined noise, heat and workload exposure, Industrial Health, 45, 4, 527–534.

de Bruijn A. (1978), Timbre-classification of complex tones, Acustica, 40, 2, 108–114.

Dobrucki A.B., Kin M.J., Kruk B. (2013), Preliminary study on the influence of headphones for listening music on hearing loss of young people, Archives of Acoustics, 38, 3, 383–387.

Green D.M., Nachmias J., Kearney J.K., Jeffress L.A. (1979), Intensity discrimination with gated and continuous sinusoids, J. Acoust. Soc. Amer., 64, 1051–1056.

Green D.M. (1983), Profile analysis: A different view of audiology intensity discrimination, American Psychologist, 38, 2, 133–142.

Gren J. (1978), Statistics – models and exercises [in Polish], PWN, Warszawa.

Jaroszewski A., Rakowski A. (1994), Loud music induced threshold shifts and damage risk prediction, Archives of Acoustics, 19, 2, 311–321.

Jaroszewski A., Fidecki T., Rogowski P. (1998), Hearing damage from exposure to music, Archives of Acoustics, 23, 1, 3–31.

Jaroszewski A., Fidecki T., Rogowski P. (1999), Exposures and hearing thresholds in music students due to training sessions, Archives of Acoustics, 24, 2, 111–118.

Jesteadt W., Wier C.C., Green D.M. (1977), Intensity discrimination as a function of frequency and sensation level, J. Acoust. Soc. Amer., 61, 169–177.

Kozłowski E., Młyński R. (2014), Effects of acoustic treatment on music teachers’ exposure to sound, Archives of Acoustics, 39, 2, 159–163.

Kruk B., Zawieja B. (2013), Improve the listening ability using e-learning methods, 134th AES Convention, Rome, Italy, preprint 8870.

Marcora S.M., Staiano W., Manning V. (2009), Mental fatigue impairs physical performance in humans, Journal of Applied Physiology, 106, 3, 857–864.

Miller G.A. (1948), The perception of short burst of noise, J. Acoust. Soc. Amer., 20, 160–170.

Moore B.C.J. (2016), Effects of sound-induced hearing loss and hearing aids on the perception of music, J. Audio Eng. Soc., 64, 3, 112–123.

Morawski S. (1967), The aesthetical studies, Part IV [in Polish], [in:] The selection of aesthetic papers, Universitas, Kraków, 2007.

O’Brien I., Beach E.F. (2016), Hearing loss, earplugs use and attitudes to hearing protection among non-orchestral ensemble musicians, J. Audio Eng. Soc., 64, 3, 132–137.

Pawlaczyk-Łuszczynska M., Dudarewicz A., Zamojska A., Śliwińska-Kowalska A. (2011), Evaluation of sound exposure and risk of hearing impairment in orchestral musicians, International Journal of Occupational Safety and Ergonomics, 17, 3, 255–269.

Rakowski A. (1996), Noise as music, Archives of Acoustics, 21, 3, 267–274.

Ristovska L., Jachova Z., Atanasova N. (2015), Frequency of the audiometric notch following excessive noise exposure, Archives of Acoustics, 40, 2, 213–221.

Rintelmann W.F., Lindberg R.F., Simiteley E.K. (1972), Temporary Threshold Shift and recovery patterns from two types of rock-and-roll music presentation, J. Acoust. Soc. Amer., 51, 1249–1255.

Royster J.D., Royster L.H., Killion M.C. (1991), Sound exposures and hearing thresholds of symphony orchestra musicians, J. Acoust. Soc. Amer., 89, 2793–2803.

Rumsey F. (2011), Mastering – art, perception, technologies, J. Audio Eng. Soc., 59, 6, 436–440.

Scharf B. (1992), Recent measurements of loudness adaptation and the definition of loudness, Proc. of the 14th ICA.

Shailer M.J., Moore B.C.J. (1983), Gap detection as a function of frequency, bandwidth and level, J. Acoust. Soc. Amer., 74, 467–473.

Sherrick C.E. Jr. (1959), Effect of background noise on the auditory intensive difference limens, J. Acoust. Soc. Amer., 31, 239–242.

Takeshima H., Suzuki Y., Kono Shunici, Toshio Sone (1988), Growth of the loudness of a tone burst with a duration up to 10 seconds, J. Acoust. Soc. Jpn., 9, 295–300.

Toole F.E., Olive S.E. (1988), The modification of timbre by resonances: perception and measurement, J. Audio Eng. Soc., 36, 3, 122–142.

ITU-R: Recommendation 1284, (1997), Methods for the subjective assessment of sound quality – general requirements, Geneva, Switzerland.

EBU Technical Recommendation R22-1999, Listening conditions for the assessment of sound programme material, EBU Geneva, Switzerland.

ISO 8253-1:2010, Acoustics – audiometric test methods – Part 1: Pure-tone air and bone conduction audiometry.

PN-EN 26189, The measurements of hearing threshold by audiometric air conduction for hearing protection [in Polish].




DOI: 10.1515/aoa-2016-0033